The PWM/tach unit has a clock and reset phandle. It needs both in order
to function correctly.
Signed-off-by: Joel Stanley <joel@jms.id.au>
--
v3:
Add the pwm reset phandle
clocks = <&syscon ASPEED_CLK_APB>;
};
+ pwm_tacho: pwm-tacho-controller@1e786000 {
+ compatible = "aspeed,ast2400-pwm-tacho";
+ #address-cells = <1>;
+ #size-cells = <0>;
+ reg = <0x1e786000 0x1000>;
+ clocks = <&syscon ASPEED_CLK_APB>;
+ resets = <&syscon ASPEED_RESET_PWM>;
+ status = "disabled";
+ };
+
vuart: serial@1e787000 {
compatible = "aspeed,ast2400-vuart";
reg = <0x1e787000 0x40>;
status = "disabled";
};
+ pwm_tacho: pwm-tacho-controller@1e786000 {
+ compatible = "aspeed,ast2500-pwm-tacho";
+ #address-cells = <1>;
+ #size-cells = <0>;
+ reg = <0x1e786000 0x1000>;
+ clocks = <&syscon ASPEED_CLK_APB>;
+ resets = <&syscon ASPEED_RESET_PWM>;
+ status = "disabled";
+ };
+
vuart: serial@1e787000 {
compatible = "aspeed,ast2500-vuart";
reg = <0x1e787000 0x40>;