net: dsa: sja1105: fix SGMII PCS being forced to SPEED_UNKNOWN instead of SPEED_10
authorVladimir Oltean <vladimir.oltean@nxp.com>
Thu, 4 Mar 2021 10:56:53 +0000 (12:56 +0200)
committerDavid S. Miller <davem@davemloft.net>
Thu, 4 Mar 2021 22:19:01 +0000 (14:19 -0800)
When using MLO_AN_PHY or MLO_AN_FIXED, the MII_BMCR of the SGMII PCS is
read before resetting the switch so it can be reprogrammed afterwards.
This works for the speeds of 1Gbps and 100Mbps, but not for 10Mbps,
because SPEED_10 is actually 0, so AND-ing anything with 0 is false,
therefore that last branch is dead code.

Do what others do (genphy_read_status_fixed, phy_mii_ioctl) and just
remove the check for SPEED_10, let it fall into the default case.

Fixes: ffe10e679cec ("net: dsa: sja1105: Add support for the SGMII port")
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/dsa/sja1105/sja1105_main.c

index 7692338730df525cf7673192ac9bac4d0f40177e..c1982615c63159a970a6c96fe215f2cc3ece67e3 100644 (file)
@@ -1922,7 +1922,7 @@ out_unlock_ptp:
                                speed = SPEED_1000;
                        else if (bmcr & BMCR_SPEED100)
                                speed = SPEED_100;
-                       else if (bmcr & BMCR_SPEED10)
+                       else
                                speed = SPEED_10;
 
                        sja1105_sgmii_pcs_force_speed(priv, speed);