Add the following attributes to the sysfs ABI.
in[0-*]_average
in[0-*]_lowest
in[0-*]_highest
in[0-*]_reset_history
in_reset_history
curr[1-*]_average
curr[1-*]_lowest
curr[1-*]_highest
curr[1-*]_reset_history
curr_reset_history
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
thumb: drivers should report the voltage values at the
"pins" of the chip.
+in[0-*]_average
+ Average voltage
+ Unit: millivolt
+ RO
+
+in[0-*]_lowest
+ Historical minimum voltage
+ Unit: millivolt
+ RO
+
+in[0-*]_highest
+ Historical maximum voltage
+ Unit: millivolt
+ RO
+
+in[0-*]_reset_history
+ Reset inX_lowest and inX_highest
+ WO
+
+in_reset_history
+ Reset inX_lowest and inX_highest for all sensors
+ WO
+
in[0-*]_label Suggested voltage channel label.
Text string
Should only be created if the driver has hints about what
Unit: milliampere
RO
+curr[1-*]_average
+ Average current use
+ Unit: milliampere
+ RO
+
+curr[1-*]_lowest
+ Historical minimum current
+ Unit: milliampere
+ RO
+
+curr[1-*]_highest
+ Historical maximum current
+ Unit: milliampere
+ RO
+
+curr[1-*]_reset_history
+ Reset currX_lowest and currX_highest
+ WO
+
+curr_reset_history
+ Reset currX_lowest and currX_highest for all sensors
+ WO
+
Also see the Alarms section for status flags associated with currents.
*********