We need to wait for 1000 ms after Data Link Layer Link Active (DLLLA)
bit reads 1b before sending configuration request. Currently pciehp
does this wait after checking Link Training (LT) bit. But we need it
before checking LT bit because LT is still set even after DLLLA bit is
set on some platforms.
Acked-by: Yinghai Lu <yinghai@kernel.org>
Tested-by: Yinghai Lu <yinghai@kernel.org>
Signed-off-by: Kenji Kaneshige <kaneshige.kenji@jp.fujitsu.com>
Signed-off-by: Jesse Barnes <jbarnes@virtuousgeek.org>
goto err_exit;
}
- /* Wait for 1 second after checking link training status */
- msleep(1000);
-
/* Check for a power fault */
if (ctrl->power_fault_detected || pciehp_query_power_fault(p_slot)) {
ctrl_err(ctrl, "Power fault on slot %s\n", slot_name(p_slot));
else
msleep(1000);
+ /*
+ * Need to wait for 1000 ms after Data Link Layer Link Active
+ * (DLLLA) bit reads 1b before sending configuration request.
+ * We need it before checking Link Training (LT) bit becuase
+ * LT is still set even after DLLLA bit is set on some platform.
+ */
+ msleep(1000);
+
retval = pciehp_readw(ctrl, PCI_EXP_LNKSTA, &lnk_status);
if (retval) {
ctrl_err(ctrl, "Cannot read LNKSTATUS register\n");