By using the managed devm_thermal_zone_of_sensor_register() we can
drop the explicit call to thermal_zone_of_sensor_unregister() in the
qoriq_tmu_remove() function, which simplifies the code a bit.
So switch to devm_thermal_zone_of_sensor_register().
Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com>
Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
if (ret < 0)
goto err_tmu;
if (ret < 0)
goto err_tmu;
- data->tz = thermal_zone_of_sensor_register(&pdev->dev, data->sensor_id,
- data, &tmu_tz_ops);
+ data->tz = devm_thermal_zone_of_sensor_register(&pdev->dev,
+ data->sensor_id,
+ data, &tmu_tz_ops);
if (IS_ERR(data->tz)) {
ret = PTR_ERR(data->tz);
dev_err(&pdev->dev,
if (IS_ERR(data->tz)) {
ret = PTR_ERR(data->tz);
dev_err(&pdev->dev,
{
struct qoriq_tmu_data *data = platform_get_drvdata(pdev);
{
struct qoriq_tmu_data *data = platform_get_drvdata(pdev);
- thermal_zone_of_sensor_unregister(&pdev->dev, data->tz);
-
/* Disable monitoring */
tmu_write(data, TMR_DISABLE, &data->regs->tmr);
/* Disable monitoring */
tmu_write(data, TMR_DISABLE, &data->regs->tmr);