maru: rotary: Change event value 76/227876/1 accepted/tizen/unified/20200324.101627 submit/tizen/20200323.012640
authorDongwoo Lee <dwoo08.lee@samsung.com>
Tue, 17 Mar 2020 02:39:31 +0000 (11:39 +0900)
committerDongwoo Lee <dwoo08.lee@samsung.com>
Tue, 17 Mar 2020 02:59:52 +0000 (11:59 +0900)
commitc0dd00d92642d3ae650c69d413984e40277f2f84
treefc555f76f13a8627e5252c24cc4d3bda1ff105f7
parentcaf02f3d74d92733aa14a3dac17bce0e8bf0d4f9
maru: rotary: Change event value

Until Tizen 5.0, for detent/bezel input device, its event value
was in between -2 and 2, but value 1, meant starting movement to
counter clockwise or clockwise, and value -1, meant moving back
to original position, never used. Change event value of the
detent/bezel device for Tizen 5.5 and later version.

It changes detent/bezel input driver event interface, so user
input framework for detent/bezel input should be also changed.

Ref: https://review.tizen.org/gerrit/#/c/platform/upstream/enlightenment/+/220346/

Change-Id: Iaa8e76de94eb4254820d93865dab9d4f7006f4e4
Signed-off-by: Seung-Woo Kim <sw0312.kim@samsung.com>
Signed-off-by: Dongwoo Lee <dwoo08.lee@samsung.com>
drivers/maru/maru_virtio_rotary.c