staging: comedi: pcl711: remove "empty acquisition" async command
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Tue, 9 Sep 2014 23:15:52 +0000 (16:15 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 11 Sep 2014 21:35:21 +0000 (14:35 -0700)
commitfe094b7e00b507e279782e0a319b7fb32e53d2d0
tree679cea69c4f7af3d5b262c3d1ae51a72691decdf
parent7be7f9c3e3f87fd1263014a14b177409b6542e54
staging: comedi: pcl711: remove "empty acquisition" async command

This driver currently allows a cmd->stop_src == TRIG_COUNT with a cmd->stop_arg
of 0. This causes the (*do_cmd) to immediately generate a COMEDI_CB_EOA event
without acquiring any data.

This "empty acquisition" async command is not really useful. Validate that the
cmd->stop_arg is >= 1 in the (*do_cmdtest) and remove the "empty acquisition"
code.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/pcl711.c