staging: comedi: pcl711: remove "empty acquisition" async command
This driver currently allows a cmd->stop_src == TRIG_COUNT with a cmd->stop_arg
of 0. This causes the (*do_cmd) to immediately generate a COMEDI_CB_EOA event
without acquiring any data.
This "empty acquisition" async command is not really useful. Validate that the
cmd->stop_arg is >= 1 in the (*do_cmdtest) and remove the "empty acquisition"
code.
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>