net/packet: check length in getsockopt() called with PACKET_HDRLEN
[ Upstream commit
fd2c83b35752f0a8236b976978ad4658df14a59f ]
In the case getsockopt() is called with PACKET_HDRLEN and optlen < 4
|val| remains uninitialized and the syscall may behave differently
depending on its value, and even copy garbage to userspace on certain
architectures. To fix this we now return -EINVAL if optlen is too small.
This bug has been detected with KMSAN.
Signed-off-by: Alexander Potapenko <glider@google.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin <alexander.levin@verizon.com>