platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table
authorMichael Haener <michael.haener@siemens.com>
Fri, 29 Nov 2019 09:16:49 +0000 (10:16 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 9 Jan 2020 09:20:03 +0000 (10:20 +0100)
commitf6cc75f1d705fe420bb95179afad6bfe4e141f21
tree76b7e7128c52edd89ba597bf08e9527bba2cd6fb
parent5c440a4d1f3a088ff0923e3853829e0a7a9b610f
platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

commit e8796c6c69d129420ee94a1906b18d86b84644d4 upstream.

The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/platform/x86/pmc_atom.c