MIPS: Loongson: Make platform serial setup always built-in.
authorAaro Koskinen <aaro.koskinen@iki.fi>
Wed, 19 Nov 2014 23:05:38 +0000 (01:05 +0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 6 Dec 2014 23:55:33 +0000 (15:55 -0800)
commitf50278a9df41ad3e519440defbf5eb82411ca393
tree3b977b2be3dc12574d3d99c972c53bba58548e6f
parent32472d9c79af7654775afd424e67779291fc9868
MIPS: Loongson: Make platform serial setup always built-in.

commit 26927f76499849e095714452b8a4e09350f6a3b9 upstream.

If SERIAL_8250 is compiled as a module, the platform specific setup
for Loongson will be a module too, and it will not work very well.
At least on Loongson 3 it will trigger a build failure,
since loongson_sysconf is not exported to modules.

Fix by making the platform specific serial code always built-in.

Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi>
Reported-by: Ralf Baechle <ralf@linux-mips.org>
Cc: linux-mips@linux-mips.org
Cc: Huacai Chen <chenhc@lemote.com>
Cc: Markos Chandras <Markos.Chandras@imgtec.com>
Patchwork: https://patchwork.linux-mips.org/patch/8533/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
arch/mips/loongson/common/Makefile