mtd: spi-nor: clear Winbond Extended Address Reg on switch to 3-byte addressing.
authorNeilBrown <neil@brown.name>
Fri, 20 Apr 2018 22:54:40 +0000 (08:54 +1000)
committerBoris Brezillon <boris.brezillon@bootlin.com>
Sat, 21 Apr 2018 08:05:23 +0000 (10:05 +0200)
commitf134fbbb4ff813dd227c9ce40b5c0b2078a77b07
tree610eab8a466e1c8a507d39505c982111f5181772
parentce5013ff3bec05cf2a8a05c75fcd520d9914d92b
mtd: spi-nor: clear Winbond Extended Address Reg on switch to 3-byte addressing.

Winbond spi-nor flash 32MB and larger have an 'Extended Address
Register' as one option for addressing beyond 16MB (Macronix
has the same concept, Spansion has EXTADD bits in the Bank Address
Register).

According to section
   8.2.7 Write Extended Address Register (C5h)

of the Winbond W25Q256FV data sheet (256M-BIT SPI flash)

   The Extended Address Register is only effective when the device is
   in the 3-Byte Address Mode.  When the device operates in the 4-Byte
   Address Mode (ADS=1), any command with address input of A31-A24
   will replace the Extended Address Register values. It is
   recommended to check and update the Extended Address Register if
   necessary when the device is switched from 4-Byte to 3-Byte Address
   Mode.

So the documentation suggests clearing the EAR after switching to
3-byte mode.  Experimentation shows that the EAR is *always* one after
the switch to 3-byte mode, so clearing the EAR is mandatory at
shutdown for a subsequent 3-byte-addressed reboot to work.

Note that some SOCs (e.g. MT7621) do not assert a reset line at normal
reboot, so we cannot rely on hardware reset.  The MT7621 does assert a
reset line at watchdog-reset.

Acked-by: Marek Vasut <marek.vasut@gmail.com>
Signed-off-by: NeilBrown <neil@brown.name>
Signed-off-by: Boris Brezillon <boris.brezillon@bootlin.com>
drivers/mtd/spi-nor/spi-nor.c
include/linux/mtd/spi-nor.h