regulator: da9052: Ensure enough delay time for .set_voltage_time_sel
authorAxel Lin <axel.lin@ingics.com>
Fri, 18 Jun 2021 14:14:11 +0000 (22:14 +0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 14 Jul 2021 14:55:56 +0000 (16:55 +0200)
commitf0b8f5682db84d1e75b22dc62f14b114ce2917db
tree82d39244d9cec7161b5f639ba88a4ffe9677a238
parent5d9e3279f5073a7048471b1797b5e02703499061
regulator: da9052: Ensure enough delay time for .set_voltage_time_sel

[ Upstream commit a336dc8f683e5be794186b5643cd34cb28dd2c53 ]

Use DIV_ROUND_UP to prevent truncation by integer division issue.
This ensures we return enough delay time.

Also fix returning negative value when new_sel < old_sel.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Link: https://lore.kernel.org/r/20210618141412.4014912-1-axel.lin@ingics.com
Signed-off-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/regulator/da9052-regulator.c