iio:bma180: Fix scale factors to report correct acceleration units
authorPeter Meerwald <pmeerw@pmeerw.net>
Wed, 16 Jul 2014 18:32:00 +0000 (19:32 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 7 Aug 2014 21:52:37 +0000 (14:52 -0700)
commitef5f195b851064b51c81c45ff981bec504eefafa
tree589fc213929b6d417ab83db123eec8e8c6af3d44
parentf7934771a2cf7b7d0042a61154f65244a8aa49a5
iio:bma180: Fix scale factors to report correct acceleration units

commit 381676d5e86596b11e22a62f196e192df6091373 upstream.

The userspace interface for acceleration sensors is documented as using
m/s^2 units [Documentation/ABI/testing/sysfs-bus-iio]

The fullscale raw values for the BMA80 corresponds to -/+ 1, 1.5, 2, etc G
depending on the selected mode.

The scale table was converting to G rather than m/s^2.
Change the scaling table to match the documented interface.

See commit 71702e6e, iio: mma8452: Use correct acceleration units,
for a related fix.

Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net>
Cc: Oleksandr Kravchenko <o.v.kravchenko@globallogic.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/accel/bma180.c