platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table
authorMichael Haener <michael.haener@siemens.com>
Fri, 29 Nov 2019 09:16:49 +0000 (10:16 +0100)
committerAndy Shevchenko <andriy.shevchenko@linux.intel.com>
Fri, 20 Dec 2019 17:00:50 +0000 (19:00 +0200)
commite8796c6c69d129420ee94a1906b18d86b84644d4
treeca760ed63c3e615191c86d151fee70771e6e86a6
parent133b2acee3871ae6bf123b8fe34be14464aa3d2c
platform/x86: pmc_atom: Add Siemens CONNECT X300 to critclk_systems DMI table

The CONNECT X300 uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this
device to the critical systems list.
Tested on CONNECT X300.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
drivers/platform/x86/pmc_atom.c