iio: adc: ti-ads1015: enable conversion when CONFIG_PM is not set
authorAkinobu Mita <akinobu.mita@gmail.com>
Thu, 20 Jul 2017 15:24:19 +0000 (00:24 +0900)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Sun, 20 Aug 2017 14:41:13 +0000 (15:41 +0100)
commite8245c68350104b6022b6783719e843d69ea7c43
treea90c5438d4d9a529a20be63c14e5574304f5d99c
parent8d0e8e795623bd6229cf48bb7777a1c456c370ed
iio: adc: ti-ads1015: enable conversion when CONFIG_PM is not set

The ADS1015 device have two operating modes, continuous conversion mode
and single-shot mode.  This driver assumes that the continuous conversion
mode is selected by runtime resume callback when the ADC result is
requested.

If CONFIG_PM is disabled, the device is always in the default single-shot
mode and no one begins a single conversion.  So the conversion register
doesn't contain valid ADC result.  Fix it by changing the continuous mode
in probe function.

Cc: Daniel Baluta <daniel.baluta@gmail.com>
Signed-off-by: Akinobu Mita <akinobu.mita@gmail.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/adc/ti-ads1015.c