mfd: rk808: Disable the under voltage detect
authorChris Zhong <zyw@rock-chips.com>
Sat, 28 Feb 2015 10:09:06 +0000 (18:09 +0800)
committerLee Jones <lee.jones@linaro.org>
Thu, 12 Mar 2015 09:07:10 +0000 (09:07 +0000)
commite19f742885e87ab9582fdf5940f214419eb9275b
tree952baa33b403a944d7602bfdc060c3ef0f8fc190
parent9a503a7d9ce0eafd4c9c4a73b9c45a53a4ed2314
mfd: rk808: Disable the under voltage detect

Rk808 has a under voltage detect function, when the voltage of buck is
under 85% the target voltage, the buck output will reset. But if the
power load is too heavy, this function maybe err, when current over
4.2A, although the voltage is normal, but RK808 mistakenly think it is
under 85%, and reset the buck. So let's disable this function.

Signed-off-by: Chris Zhong <zyw@rock-chips.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
drivers/mfd/rk808.c