KVM: PPC: Book3S HV: Check for updated HDSISR on P9 HDSI exception
On POWER9 DD2.1 and below, sometimes on a Hypervisor Data Storage
Interrupt (HDSI) the HDSISR is not be updated at all.
To work around this we put a canary value into the HDSISR before
returning to a guest and then check for this canary when we take a
HDSI. If we find the canary on a HDSI, we know the hardware didn't
update the HDSISR. In this case we return to the guest to retake the
HDSI which should correctly update the HDSISR the second time HDSI
entry.
After talking to Paulus we've applied this workaround to all POWER9
CPUs. The workaround of returning to the guest shouldn't ever be
triggered on well behaving CPU. The extra instructions should have
negligible performance impact.
Signed-off-by: Michael Neuling <mikey@neuling.org>
Signed-off-by: Paolo Bonzini <pbonzini@redhat.com>