at86rf230: add support for calibration timeout
This patch adds a handling for calibration if we are 5 minutes in PLL
state. I first tried to implement the calibration functionality in
TX_ON state via register values CF_START and DCU_START, but this occurs
a one second delay at each calibration time.
An another solution to start a calibration is to switch from TRX_OFF
state into TX_ON, then a calibration is done automatically by
transceiver. This method will be used in this patch, after each transmit
of a frame we check with jiffies if the PLL is set 5 minutes without
doing a TRX_OFF->(TX_ON || RX_AACK_ON) or channel switch. The worst case
would be a transceiver in receiving mode only, but this is under normal
operation very unlikely.
Signed-off-by: Alexander Aring <alex.aring@gmail.com>
Cc: Phoebe Buckheister <phoebe.buckheister@itwm.fraunhofer.de>
Cc: Werner Almesberger <werner@almesberger.net>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>