power: supply: axp20x_battery: properly report current when discharging
authorEvgeny Boger <boger@wirenboard.com>
Wed, 12 Jan 2022 08:47:27 +0000 (11:47 +0300)
committerSebastian Reichel <sebastian.reichel@collabora.com>
Tue, 1 Feb 2022 10:18:47 +0000 (11:18 +0100)
commitd4f408cdcd26921c1268cb8dcbe8ffb6faf837f3
tree48fe5ff3769e1ff50f44d6e08b56241902bb2952
parentba18dad0fb880cd29aa97b6b75560ef14d1061ba
power: supply: axp20x_battery: properly report current when discharging

As stated in [1], negative current values are used for discharging
batteries.

AXP PMICs internally have two different ADC channels for shunt current
measurement: one used during charging and one during discharging.
The values reported by these ADCs are unsigned.
While the driver properly selects ADC channel to get the data from,
it doesn't apply negative sign when reporting discharging current.

[1] Documentation/ABI/testing/sysfs-class-power

Signed-off-by: Evgeny Boger <boger@wirenboard.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
drivers/power/supply/axp20x_battery.c