net: mscc: ocelot: be able to reuse a devlink_port after teardown
There are cases where we would like to continue probing the switch even
if one port has failed to probe. When that happens, we need to
unregister a devlink_port of type DEVLINK_PORT_FLAVOUR_PHYSICAL and
re-register it of type DEVLINK_PORT_FLAVOUR_UNUSED.
This is fine, except when calling devlink_port_attrs_set on a structure
on which devlink_port_register has been previously called, there is a
WARN_ON in devlink_port_attrs_set that devlink_port->devlink must be
NULL.
So don't assume that the memory behind dlp is clean when calling
ocelot_port_devlink_init, just zero-initialize it.
Signed-off-by: Horatiu Vultur <horatiu.vultur@microchip.com>
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>