hwmon: (tps23861) set current shunt value
authorRobert Marko <robert.marko@sartura.hr>
Wed, 9 Jun 2021 22:07:27 +0000 (00:07 +0200)
committerGuenter Roeck <linux@roeck-us.net>
Thu, 10 Jun 2021 15:38:52 +0000 (08:38 -0700)
commitb325d3526e14942d42c392c2ac9fbea59c22894c
tree2e7cac107413afa0181ad44f83df9845b028bb98
parentfb8543fb863e89baa433b4d716d73395caa1b7f4
hwmon: (tps23861) set current shunt value

TPS23861 has a configuration bit for setting of the
current shunt value used on the board.
Its bit 0 of the General Mask 1 register.

According to the datasheet bit values are:
0 for 255 mOhm (Default)
1 for 250 mOhm

So, configure the bit before registering the hwmon
device according to the value passed in the DTS or
default one if none is passed.

This caused potentially reading slightly skewed values
due to max current value being 1.02A when 250mOhm shunt
is used instead of 1.0A when 255mOhm is used.

Fixes: fff7b8ab2255 ("hwmon: add Texas Instruments TPS23861 driver")
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
Link: https://lore.kernel.org/r/20210609220728.499879-2-robert.marko@sartura.hr
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
drivers/hwmon/tps23861.c