platform/x86/siemens: simatic-ipc: fix logical error for BX-59A
The variable "ledmode" is missing from if statement that leads to
a logical error. Add the missing variable to the if condition.
Fixes:
b8af77951941 ("platform/x86/siemens: simatic-ipc: add new models BX-56A/BX-59A")
Reported-by: kernel test robot <lkp@intel.com>
Closes: https://lore.kernel.org/oe-kbuild-all/
202307312322.Aa8upHWK-lkp@intel.com/
Reviewed-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com>
Signed-off-by: xingtong.wu <xingtong.wu@siemens.com>
Link: https://lore.kernel.org/r/20430802173515.2363-2-xingtong_wu@163.com