media: imx-csi: Move crop/compose reset after filling default mbus fields
authorSteve Longerbeam <slongerbeam@gmail.com>
Wed, 9 Jan 2019 18:30:12 +0000 (13:30 -0500)
committerMauro Carvalho Chehab <mchehab+samsung@kernel.org>
Wed, 16 Jan 2019 19:15:39 +0000 (14:15 -0500)
commitab2f05cdb15421c1e57d3345852f6fb1405e3398
treeb9f16e9b7324f2e35b2eae30930fe3bb2dcfc4d8
parent6e537b58de772cfc89d4fbd0cddd0c1de5f93822
media: imx-csi: Move crop/compose reset after filling default mbus fields

If caller passes un-initialized field type V4L2_FIELD_ANY to CSI
sink pad, the reset CSI crop window would not be correct, because
the crop window depends on a valid input field type. To fix move
the reset of crop and compose windows to after the call to
imx_media_fill_default_mbus_fields().

Signed-off-by: Steve Longerbeam <slongerbeam@gmail.com>
Reviewed-by: Philipp Zabel <p.zabel@pengutronix.de>
Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@kernel.org>
drivers/staging/media/imx/imx-media-csi.c