pwm: mediatek: always use bus clock for PWM on MT7622
authorDaniel Golle <daniel@makrotopia.org>
Fri, 2 Dec 2022 18:35:08 +0000 (19:35 +0100)
committerThierry Reding <thierry.reding@gmail.com>
Tue, 6 Dec 2022 11:46:04 +0000 (12:46 +0100)
commitaa3c668f2f98856af96e13f44da6ca4f26f0b98c
tree8c95de41d5ffbcbddc985b36dcda7a8c2ab65fc1
parent07d8d8d29aa76f3c28020a9c914cc890eb86a48c
pwm: mediatek: always use bus clock for PWM on MT7622

According to MT7622 Reference Manual for Development Board v1.0 the PWM
unit found in the MT7622 SoC also comes with the PWM_CK_26M_SEL register
at offset 0x210 just like other modern MediaTek ARM64 SoCs.
And also MT7622 sets that register to 0x00000001 on reset which is
described as 'Select 26M fix CLK as BCLK' in the datasheet.
Hence set has_ck_26m_sel to true also for MT7622 which results in the
driver writing 0 to the PWM_CK_26M_SEL register which is described as
'Select bus CLK as BCLK'.

Fixes: 0c0ead76235db0 ("pwm: mediatek: Always use bus clock")
Signed-off-by: Daniel Golle <daniel@makrotopia.org>
Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Link: https://lore.kernel.org/r/Y1iF2slvSblf6bYK@makrotopia.org
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
drivers/pwm/pwm-mediatek.c