hwmon: (pmbus) Add Vin unit off handling
If there is an input undervoltage fault, reported in STATUS_INPUT
command response, there is quite likely a "Unit Off For Insufficient
Input Voltage" condition as well.
Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit
attributes to include both bits in the mask for clearing faults.
If an input undervoltage fault occurs, causing a unit off for
insufficient input voltage, but the unit is off bit is not cleared, the
STATUS_WORD will not be updated to clear the input fault condition.
Including the unit is off bit (bit 3) allows for the input fault
condition to completely clear.
Signed-off-by: Brandon Wyman <bjwyman@gmail.com>
Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com
Fixes: b4ce237b7f7d3 ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers")
[groeck: Dropped unnecessary ()]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>