MIPS: perf: Fix wrong check condition of Loongson event IDs
authorTiezhu Yang <yangtiezhu@loongson.cn>
Thu, 27 Aug 2020 08:03:08 +0000 (16:03 +0800)
committerThomas Bogendoerfer <tsbogend@alpha.franken.de>
Tue, 1 Sep 2020 11:52:33 +0000 (13:52 +0200)
commita231995700c392c0807da95deea231b23fc51a3c
tree504d4428ab7db712eaf8d141d0ee5c8bc38094e2
parent91dbd73a1739039fa7e9fe5c0169f2817a7f7670
MIPS: perf: Fix wrong check condition of Loongson event IDs

According to the user's manual chapter 8.2.1 of Loongson 3A2000 CPU [1]
and 3A3000 CPU [2], we should take some event IDs such as 274, 358, 359
and 360 as valid in the check condition, otherwise they are recognized
as "not supported", fix it.

[1] http://www.loongson.cn/uploadfile/cpu/3A2000/Loongson3A2000_user2.pdf
[2] http://www.loongson.cn/uploadfile/cpu/3A3000/Loongson3A3000_3B3000user2.pdf

Fixes: e9dfbaaeef1c ("MIPS: perf: Add hardware perf events support for new Loongson-3")
Signed-off-by: Tiezhu Yang <yangtiezhu@loongson.cn>
Acked-by: Huang Pei <huangpei@loongson.cn>
Signed-off-by: Thomas Bogendoerfer <tsbogend@alpha.franken.de>
arch/mips/kernel/perf_event_mipsxx.c