nvme-fc: remove double put reference if admin connect fails
authorJames Smart <jsmart2021@gmail.com>
Wed, 29 Nov 2017 23:11:37 +0000 (15:11 -0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 3 Mar 2018 09:24:22 +0000 (10:24 +0100)
commita1aef5ce2abef719d1881bd22e0e875cca8f7b6f
tree01e715761946a52dde7d174bbc427a52e5b9bad9
parent4d9f6272917815f5ac5821ab6163045e74903f0d
nvme-fc: remove double put reference if admin connect fails

[ Upstream commit 4596e752db02d47038cd7c965419789ab15d1985 ]

There are two put references in the failure case of initial
create_association. The first put actually frees the controller, thus the
second put references freed memory.

Remove the unnecessary 2nd put.

Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Sasha Levin <alexander.levin@verizon.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/nvme/host/fc.c