cmd: date: rtc: Update command to read the first RTC with seq 0
authorMichal Simek <michal.simek@xilinx.com>
Thu, 29 Jul 2021 10:59:12 +0000 (12:59 +0200)
committerMichal Simek <michal.simek@xilinx.com>
Fri, 6 Aug 2021 07:32:02 +0000 (09:32 +0200)
commita1ae55ee7f8df911649a0cfa5eba3ea88bae92ab
treed10e72ac7a6cdc96e1b54e11fd455d97b8c4b4dd
parent23a328769a2638e87131198ad1e93000f69d6393
cmd: date: rtc: Update command to read the first RTC with seq 0

RTCs are using sequence number defined in aliases node. Date command with
DM_RTC enabled is looking for the first RTC with index 0. But when
RTC_EMULATION is enabled it gets likely most of the time index 0 even when
system has rtc0 device via aliases node and gets sequence number 0.
That's why extend the code to look for sequence 0 number first. If this
fails continue to use existing device with index 0.

Signed-off-by: Michal Simek <michal.simek@xilinx.com>
cmd/date.c