Merge tag 'iio-fixes-for-3.14b' of git://git.kernel.org/pub/scm/linux/kernel/git...
authorGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 8 Feb 2014 21:29:18 +0000 (13:29 -0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 8 Feb 2014 21:29:18 +0000 (13:29 -0800)
commita0f452520211385522aad5bd12d90aa59f17e094
treeb273b91937b2ecede65e07dc9ceae926c21a3c4e
parent6b89db36b3ab7c4b99027873e1de4be8d07387d4
parent55b40d37311807a6bb2acdae0df904f54a0da3ae
Merge tag 'iio-fixes-for-3.14b' of git://git./linux/kernel/git/jic23/iio into staging-linus

Jonathan writes:

Second round of IIO fixes for the 3.14 cycle.

Another mixed bag, including some that were not in round 1 because
they applied to elements that went in during the merge window whereas
round 1 predated that.  I have been effectively out of action for 3 weeks
so will take a little while to catch up with my backlog.

* mag3110 - report busy in read_raw / write_raw when buffered capture
  is underway to avoid either changing the characteristics of the capture or
  causing capture issues by reading data destined for the buffer.
* mag3110 - fix a failure to specify leading zeros when formatting a decimal
  number.
* lradc - fix a buffer overflow and incorrect reporting of scale for voltage
  channel 15
* lradc - drop some scale_available attributes for elements that don't actually
  exist.  These could otherwise cause some interesting issues for userspace.
* ad799x - a typo in the events information mask resulted in some nasty crashes
  on failed probes.
* ak8975 - fix scale attribute output to avoid incorrect intepretation of
  readings in userspace.
* adis16400 - make sure the timestamp is the last element in all channel_spec
  arrays as this assumption is made by the buffer filling code, but was not
  true previously.
* bma180 - correctly use modifiers to distinguish the channels rather than
  indexes.  This brings the abi inline with the standard option for 3 axis
  accelerometers.
* max1363 - use devm_regulator_get_optional instead of the non optional case
  to allow the device to successfully probe when a regulator is not specified.