iio: ak8975: Fix calculation formula for convert micro tesla to gauss unit
authorBeomho Seo <beomho.seo@samsung.com>
Wed, 2 Apr 2014 08:15:00 +0000 (09:15 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sat, 22 Feb 2014 21:32:27 +0000 (13:32 -0800)
commit9b53049a956cb9db81bf268c75b5538c295056c6
treefe90a41bf6732683d3a837dbe296513d5577db57
parent0f543e6a6b01a50b1514ec3f9295aa62488a4bd7
iio: ak8975: Fix calculation formula for convert micro tesla to gauss unit

commit bef44abccb2677e8d16e50b75316d4fd1061be81 upstream.

This effects the reported scale of the raw values, and thus userspace
applications that use this value.

One micro tesla equal 0.01 gauss. So I have fixed calculation formula And add RAW_TO_GAUSS macro.
ASA is in the range of 0 to 255. If multiply 0.003, calculation result(in_magn_[*]_scale) is
always 0. So multiply 3000 and return and IIO_VAL_INT_PLUS_MICRO.
As a result, read_raw call back function return accurate scale value.

Signed-off-by: Beomho Seo <beomho.seo@samsung.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/magnetometer/ak8975.c