ARM: dts: meson8: correct uart_B and uart_C clock references
On Meson8 uart_B and uart_C do not work, because they are relying on
incorrect clocks. Change the references of pclk to the correct CLKID
(UART1 for uart_B and UART2 for uart_C), to allow use of the two uarts.
This was originally reported by Hans-Frieder Vogt for Meson8b [0], but
the same bug is also present in meson8.dtsi
[0] https://lore.kernel.org/linux-amlogic/trinity-
bf20bcb9-790b-4ab9-99e3-
0831ef8257f4-
1680878185420@3c-app-gmx-bap55/
Fixes:
57007bfb5469 ("ARM: dts: meson8: Fix the UART device-tree schema validation")
Reported-by: Hans-Frieder Vogt <hfdevel@gmx.net> # for meson8b.dtsi
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Link: https://lore.kernel.org/r/20230516203029.1031174-1-martin.blumenstingl@googlemail.com
Signed-off-by: Neil Armstrong <neil.armstrong@linaro.org>