net: ks8851: Set initial carrier state to down
authorLukas Wunner <lukas@wunner.de>
Wed, 20 Mar 2019 14:02:00 +0000 (15:02 +0100)
committerDavid S. Miller <davem@davemloft.net>
Wed, 20 Mar 2019 19:43:52 +0000 (12:43 -0700)
commit9624bafa5f6418b9ca5b3f66d1f6a6a2e8bf6d4c
tree7cbe85f2b876509752d06b580fc4d4f555831722
parentd268f31552794abf5b6aa5af31021643411f25f5
net: ks8851: Set initial carrier state to down

The ks8851 chip's initial carrier state is down. A Link Change Interrupt
is signaled once interrupts are enabled if the carrier is up.

The ks8851 driver has it backwards by assuming that the initial carrier
state is up. The state is therefore misrepresented if the interface is
opened with no cable attached. Fix it.

The Link Change interrupt is sometimes not signaled unless the P1MBSR
register (which contains the Link Status bit) is read on ->ndo_open().
This might be a hardware erratum. Read the register by calling
mii_check_link(), which has the desirable side effect of setting the
carrier state to down if the cable was detached while the interface was
closed.

Signed-off-by: Lukas Wunner <lukas@wunner.de>
Cc: Frank Pavlic <f.pavlic@kunbus.de>
Cc: Ben Dooks <ben.dooks@codethink.co.uk>
Cc: Tristram Ha <Tristram.Ha@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/micrel/ks8851.c