net: phy: mscc-miim: use more reasonable delays
The MSCC MIIM MDIO driver uses delays to read poll a status register. I
made multiple tests on a Ocelot PCS120 platform which led me to reduce
those delays. The delay in between which the polling function is allowed
to sleep is reduced from 100us to 50us which in almost all cases is a
good value to succeed at the first retry. The overall delay is also
lowered as the prior value was really way to high, 10000us is large
enough.
Signed-off-by: Antoine Tenart <antoine.tenart@bootlin.com>
Reviewed-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>