iio: pressure: dps310: Adjust Timeout Settings
authorLakshmi Yadlapati <lakshmiy@us.ibm.com>
Tue, 29 Aug 2023 18:02:22 +0000 (13:02 -0500)
committerJonathan Cameron <Jonathan.Cameron@huawei.com>
Thu, 5 Oct 2023 17:06:45 +0000 (18:06 +0100)
commit901a293fd96fb9bab843ba4cc7be3094a5aa7c94
tree79329f26f14cb8158d44cfb3d94038f024ba3067
parentc9b9cfe7d342683f624a89c3b617be18aff879e8
iio: pressure: dps310: Adjust Timeout Settings

The DPS310 sensor chip has been encountering intermittent errors while
reading the sensor device across various system designs. This issue causes
the chip to become "stuck," preventing the indication of "ready" status
for pressure and temperature measurements in the MEAS_CFG register.

To address this issue, this commit fixes the timeout settings to improve
sensor stability:
- After sending a reset command to the chip, the timeout has been extended
  from 2.5 ms to 15 ms, aligning with the DPS310 specification.
- The read timeout value of the MEAS_CFG register has been adjusted from
  20ms to 30ms to match the specification.

Signed-off-by: Lakshmi Yadlapati <lakshmiy@us.ibm.com>
Fixes: 7b4ab4abcea4 ("iio: pressure: dps310: Reset chip after timeout")
Link: https://lore.kernel.org/r/20230829180222.3431926-2-lakshmiy@us.ibm.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
drivers/iio/pressure/dps310.c