staging: comedi: rtd520: prevent "empty acquisition" async command
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Tue, 9 Sep 2014 23:16:00 +0000 (16:16 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 11 Sep 2014 21:35:21 +0000 (14:35 -0700)
commit8c602c498cd88faa78e17acc7efa29a36012e728
treecb4e101248bfd1ef7b6e9b9d771dd45a4fadb784
parent1e2e39effd11ca7c09cc47aff9e99d976109bbe8
staging: comedi: rtd520: prevent "empty acquisition" async command

This driver currently allows a cmd->stop_src == TRIG_COUNT with a cmd->stop_arg
of 0. The (*do_cmd) then sets up and starts the command without handling the "empty
acquisition". This results in the interrupt function trying to transfer 0 data
samples.

Validate that the cmd->stop_arg is >= 1 in the (*do_cmdtest) to prevent the
"empty acquisition".

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/rtd520.c