ASoC: Fix bias power down of non-DAPM codec
Currently bias of non-DAPM codec will be powered down (standby/off) whenever
there is a stream stop. This is wrong in simultaneous playback/capture since
the bias is put down immediately after stopping the first stream.
Fix this by using the codec->active count when figuring out the needed bias
level after stream stop.
Signed-off-by: Jarkko Nikula <jhnikula@gmail.com>
Acked-by: Liam Girdwood <lrg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>