pwm: fsl-ftm: Fix clock enable/disable when using PM
authorStefan Agner <stefan@agner.ch>
Mon, 23 Nov 2015 22:45:07 +0000 (14:45 -0800)
committerThierry Reding <thierry.reding@gmail.com>
Wed, 16 Dec 2015 15:54:32 +0000 (16:54 +0100)
commit816aec2325e620b6454474372a21f90a8740cb28
tree6db9059a4e4673662a15aaebc67b4791b6ccb42d
parent37670676a122a38e72ecd9dac0feff2a3dac967f
pwm: fsl-ftm: Fix clock enable/disable when using PM

A FTM PWM instance enables/disables three clocks: The bus clock, the
counter clock and the PWM clock. The bus clock gets enabled on
pwm_request, whereas the counter and PWM clocks will be enabled upon
pwm_enable.

The driver has three closesly related issues when enabling/disabling
clocks during suspend/resume:
- The three clocks are not treated differently in regards to the
  individual PWM state enabled/requested. This can lead to clocks
  getting disabled which have not been enabled in the first place
  (a PWM channel which only has been requested going through
  suspend/resume).

- When entering suspend, the current behavior relies on the
  FTM_OUTMASK register: If a PWM output is unmasked, the driver
  assumes the clocks are enabled. However, some PWM instances
  have only 2 channels connected (e.g. Vybrid's FTM1). In that case,
  the FTM_OUTMASK reads 0x3 if all channels are disabled, even if
  the code wrote 0xff to it before. For those PWM instances, the
  current approach to detect enabled PWM signals does not work.

- A third issue applies to the bus clock only, which can get enabled
  multiple times (once for each PWM channel of a PWM chip). This is
  fine, however when entering suspend mode, the clock only gets
  disabled once.

This change introduces a different approach by relying on the enable
and prepared counters of the clock framework and using the frameworks
PWM signal states to address all three issues.

Clocks get disabled during suspend and back enabled on resume
regarding to the PWM channels individual state (requested/enabled).

Since we do not count the clock enables in the driver, this change no
longer clears the Status and Control registers Clock Source Selection
(FTM_SC[CLKS]). However, since we disable the selected clock anyway,
and we explicitly select the clock source on reenabling a PWM channel
this approach should not make a difference in practice.

Signed-off-by: Stefan Agner <stefan@agner.ch>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
drivers/pwm/pwm-fsl-ftm.c