mmc: sdhci: SDMA may use Auto-CMD23 in v4 mode
When Host Version 4 Enable is set to 1, SDMA uses ADMA System Address
register (05Fh-058h) instead of using register (000h-004h) to indicate
its system address of data location. The register (000h-004h) is
re-assigned to 32-bit Block Count and Auto CMD23 argument, so then SDMA
may use Auto CMD23.
Signed-off-by: Chunyan Zhang <zhang.chunyan@linaro.org>
Acked-by: Adrian Hunter <adrian.hunter@intel.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>