pwm: berlin: Ensure configuring period and duty_cycle isn't wrongly skipped
authorUwe Kleine-König <u.kleine-koenig@pengutronix.de>
Thu, 1 Jul 2021 08:27:54 +0000 (10:27 +0200)
committerThierry Reding <thierry.reding@gmail.com>
Thu, 8 Jul 2021 14:09:17 +0000 (16:09 +0200)
commit7d6d4aaf2809f209c7d6bcab2f9ae76797051cfa
treea008d12d1019aaf0a44e36eed3630547bf585390
parent25f70b8f3d15b8c188ecb49c6007b86f3e775c20
pwm: berlin: Ensure configuring period and duty_cycle isn't wrongly skipped

As the last call to berlin_pwm_apply() might have exited early if
state->enabled was false, the values for period and duty_cycle stored in
pwm->state might not have been written to hardware and it must be
ensured that they are configured before enabling the PWM.

Fixes: 30dffb42fcd4 ("pwm: berlin: Implement .apply() callback")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
drivers/pwm/pwm-berlin.c