can: sja1000: clear interrupts on start
authorMirza Krak <mirza.krak@hostmobility.com>
Tue, 10 Nov 2015 13:59:34 +0000 (14:59 +0100)
committerMarc Kleine-Budde <mkl@pengutronix.de>
Mon, 23 Nov 2015 08:35:21 +0000 (09:35 +0100)
commit7cecd9ab80f43972c056dc068338f7bcc407b71c
treefc0323193a1434c3478c1a557382af223f2a34b0
parent4c6980462f32b4f282c5d8e5f7ea8070e2937725
can: sja1000: clear interrupts on start

According to SJA1000 data sheet error-warning (EI) interrupt is not
cleared by setting the controller in to reset-mode.

Then if we have the following case:
- system is suspended (echo mem > /sys/power/state) and SJA1000 is left
  in operating state
- A bus error condition occurs which activates EI interrupt, system is
  still suspended which means EI interrupt will be not be handled nor
  cleared.

If the above two events occur, on resume there is no way to return the
SJA1000 to operating state, except to cycle power to it.

By simply reading the IR register on start we will clear any previous
conditions that could be present.

Signed-off-by: Mirza Krak <mirza.krak@hostmobility.com>
Reported-by: Christian Magnusson <Christian.Magnusson@semcon.com>
Cc: linux-stable <stable@vger.kernel.org>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
drivers/net/can/sja1000/sja1000.c