ab8500-fg: Adjust for RF bursts voltage drops
authorHakan Berg <hakan.berg@stericsson.com>
Thu, 10 May 2012 06:43:25 +0000 (08:43 +0200)
committerLee Jones <lee.jones@linaro.org>
Wed, 23 Jan 2013 11:33:03 +0000 (11:33 +0000)
commit75f2a219ff11e6707903194009656820bba2d5c6
tree67102e924ccc855ef1529aa34b7d95acb3ef9a82
parentff38090aa2e1423e130cc72e790145bad7de8215
ab8500-fg: Adjust for RF bursts voltage drops

Changed conditions for restarting low battery measurements counter
and adjusted the interval between measurements to avoid RF burst
induced voltage drops, and to shorten time to decide to shut down.

Signed-off-by: Hakan Berg <hakan.berg@stericsson.com>
Signed-off-by: Martin Bergstrom <martin.bergstrom@stericsson.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Reviewed-by: Jonas ABERG <jonas.aberg@stericsson.com>
Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com>
drivers/power/ab8500_fg.c