iio: Fix two mpl3115 issues in measurement conversion
authorPeter Meerwald <pmeerw@pmeerw.net>
Tue, 20 May 2014 07:36:00 +0000 (08:36 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 26 Jun 2014 19:15:42 +0000 (15:15 -0400)
commit74c68519ea6c2ef5e1b5a0a588647048865e200d
treeb669acf09b7da516eb2d00f7b48b427ed4ec8f78
parent48c941af0db1354ebef774db3d7eee1bb38f534a
iio: Fix two mpl3115 issues in measurement conversion

commit d29f592929489d0a7c414396fae28119f3d280e1 upstream.

(i) pressure is 20-bit unsigned, not signed; the buffer description
is incorrect; for raw reads, this is just cosmetic

(ii) temperature is 12-bit signed, not 16-bit; this affects
readout of temperatures below zero as the sign bit is incorrectly
processed

reported via private mail

Signed-off-by: Peter Meerwald <pmeerw@pmeerw.net>
Reported-by: Robert Deliƫn <robert@delien.nl>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/iio/pressure/mpl3115.c