While LE scanning, send first RPA instead of IDA
[Model] All
[BinType] AP
[Customer] OPEN
[Issue#] N/A
[Request] Internal
[Occurrence Version] N/A
[Problem] Durning LE scanning, unable to find a paired RPA device
[Cause & Measure] Bluez report it as IDA instead of PRA. Handle it as RPA
[Checking Method] LE scan for paired RPA device
[Team] Convergence BT
[Developer] Injun Yang
[Solution company] Samsung
[Change Type] Specification change
Change-Id: I890fda13825172f759d4f4f317dfd053504c4c4b
Signed-off-by: injun.yang <injun.yang@samsung.com>