altera tse: Error-Bit on tx-avalon-stream always set.
authorAndreas Oetken <ennoerlangen@gmail.com>
Mon, 20 Apr 2015 22:16:38 +0000 (00:16 +0200)
committerDavid S. Miller <davem@davemloft.net>
Tue, 21 Apr 2015 02:01:16 +0000 (22:01 -0400)
commit71cd26e76a9514715df7880db0a8f7c37c17149a
treed5b4569142e55730bbdf3881cd4569506d5a4120
parent47cf1e659e0f44c29788a96345862c44c6a48c89
altera tse: Error-Bit on tx-avalon-stream always set.

The Error-Bit on the avalon streaming interface of the
tx-dma-channel was always set. In SGMII configurations
this leads to error-symbols on the PCS and packet-rejection
on the receiver side (e.g. SGMII/1000Base-X connected switch).

This only applies to the tse-configuration with MSGDMA.

This issue was detected and fixed on a custom board with
a direct connection to a Marvell switch in SGMII-PHY-Mode.
(incl. custom patches for SGMII-PCS).

According to the datasheet if ff_tx_err (avalon-streaming)
is set it is forwarded to gm_tx_err. As a result the PCS
is forwarding the error by sending a "/V/"-caracter.

Signed-off-by: Andreas Oetken <ennoerlangen@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/altera/altera_msgdmahw.h