iio: adc: xilinx-xadc: Correct temperature offset/scale for UltraScale
authorRobert Hancock <robert.hancock@calian.com>
Fri, 15 Sep 2023 00:10:19 +0000 (18:10 -0600)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 2 Nov 2023 08:35:30 +0000 (09:35 +0100)
commit6ec84059b5e118c9fd8dc79913e8036f98530fe3
tree41194a50660dab48b00e71d46df8aa34b519c4cb
parente26fd381bf1109c4aca704183439b4eca770b91d
iio: adc: xilinx-xadc: Correct temperature offset/scale for UltraScale

commit e2bd8c28b9bd835077eb65715d416d667694a80d upstream.

The driver was previously using offset and scale values for the
temperature sensor readings which were only valid for 7-series devices.
Add per-device-type values for offset and scale and set them appropriately
for each device type.

Note that the values used for the UltraScale family are for UltraScale+
(i.e. the SYSMONE4 primitive) using the internal reference, as that seems
to be the most common configuration and the device tree values Xilinx's
device tree generator produces don't seem to give us anything to tell us
which configuration is used. However, the differences within the UltraScale
family seem fairly minor and it's closer than using the 7-series values
instead in any case.

Fixes: c2b7720a7905 ("iio: xilinx-xadc: Add basic support for Ultrascale System Monitor")
Signed-off-by: Robert Hancock <robert.hancock@calian.com>
Acked-by: O'Griofa, Conall <conall.ogriofa@amd.com>
Tested-by: O'Griofa, Conall <conall.ogriofa@amd.com>
Link: https://lore.kernel.org/r/20230915001019.2862964-3-robert.hancock@calian.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>