smiapp: Take mutex during PLL update in sensor initialisation
authorSakari Ailus <sakari.ailus@linux.intel.com>
Tue, 16 Sep 2014 18:57:07 +0000 (15:57 -0300)
committerJiri Slaby <jslaby@suse.cz>
Wed, 28 Jan 2015 08:27:34 +0000 (09:27 +0100)
commit6b77d12ba98e4e0217131f0029ad298487338626
tree915d01e743e497ad7f104133ec61edb913513731
parented1b779dd3e9844244b2a05426b11c3a7d273b03
smiapp: Take mutex during PLL update in sensor initialisation

commit f85698cd296f08218a7750f321e94607da128600 upstream.

The mutex does not serialise anything in this case but avoids a lockdep
warning from the control framework.

Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com>
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: Mauro Carvalho Chehab <mchehab@osg.samsung.com>
Signed-off-by: Jiri Slaby <jslaby@suse.cz>
drivers/media/i2c/smiapp/smiapp-core.c