rtc: da9063: set range
authorAlexandre Belloni <alexandre.belloni@bootlin.com>
Thu, 21 Mar 2019 10:15:56 +0000 (11:15 +0100)
committerAlexandre Belloni <alexandre.belloni@bootlin.com>
Thu, 4 Apr 2019 08:07:10 +0000 (10:07 +0200)
commit5ff404d1496e131f2fccc100cfc153ee2b34b4d3
tree02ce1d13ab24ef8b935df4551c00ac88a064e7f9
parent64bef02c92fa16c9f1d1d1770154f4d74b8f04a0
rtc: da9063: set range

The DA9062 and DA9063 have a year register that can go up to 0x3F.

Acked-by: Steve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
drivers/rtc/rtc-da9063.c