staging: comedi: ni_labpc: correct differential channel sequence for AI commands
authorIan Abbott <abbotti@mev.co.uk>
Wed, 27 Feb 2013 12:52:45 +0000 (12:52 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sun, 3 Mar 2013 22:09:07 +0000 (06:09 +0800)
commit5e6af63de116db55be85da4374441f7963d11281
tree57d7a705fefbe695381bff7516b6bf7acc2d1e6c
parentd81d788db85abd39fd7753e2482f748c48de202a
staging: comedi: ni_labpc: correct differential channel sequence for AI commands

Commit 4c4bc25d0fa6beaf054c0b4c3b324487f266c820 upstream.

Tuomas <tvainikk _at_ gmail _dot_ com> reported problems getting
meaningful output from a Lab-PC+ in differential mode for AI cmds, but
AI insn reads gave correct readings.  He tracked it down to two
problems, one of which is addressed by this patch.

It seems the setting of the channel bits for particular scanning modes
was incorrect for differential mode.  (Only half the number of channels
are available in differential mode; comedi refers to them as channels 0,
1, 2 and 3, but the hardware documentation refers to them as channels 0,
2, 4 and 6.)  In differential mode, the setting of the channel enable
bits in the command1 register should depend on whether the scan enable
bit is set.  Effectively, we need to double the comedi channel number
when the scan enable bit is not set in differential mode.  The scan
enable bit gets set when the AI scan mode is `MODE_MULT_CHAN_UP` or
`MODE_MULT_CHAN_DOWN`, and gets cleared when the AI scan mode is
`MODE_SINGLE_CHAN` or `MODE_SINGLE_CHAN_INTERVAL`.  The existing test
for whether the comedi channel number needs to be doubled in
differential mode is incorrect in `labpc_ai_cmd()`.  This patch corrects
the test.

Thanks to Tuomas for suggesting the fix.

Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/ni_labpc.c