thermal/core/thermal_of: Stop zone device before unregistering it
authorDmitry Osipenko <digetx@gmail.com>
Wed, 16 Jun 2021 19:04:13 +0000 (22:04 +0300)
committerDaniel Lezcano <daniel.lezcano@linaro.org>
Sun, 4 Jul 2021 16:28:04 +0000 (18:28 +0200)
commit5e5c9f9a75fc4532980c2e699caf8a36070a3a2e
tree7f98c38316c22849c4bebd0ab69293d0f377d308
parent1aab6b81af3c96e3181911140d2528e112335bef
thermal/core/thermal_of: Stop zone device before unregistering it

Zone device is enabled after thermal_zone_of_sensor_register() completion,
but it's not disabled before senor is unregistered, leaving temperature
polling active. This results in accessing a disabled zone device and
produces a warning about this problem. Stop zone device before
unregistering it in order to fix this "use-after-free" problem.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/20210616190417.32214-3-digetx@gmail.com
drivers/thermal/thermal_of.c