regulator: pwm: Fix machine constraints application
If the zero duty cycle doesn't correspond to any voltage in the voltage
table, the PWM regulator returns an -EINVAL from get_voltage_sel() which
results in the core erroring out with a "failed to get the current
voltage" and ending up not applying the machine constraints.
Instead, return -ENOTRECOVERABLE which makes the core set the voltage
since it's at an unknown value.
For example, with this device tree:
fooregulator {
compatible = "pwm-regulator";
pwms = <&foopwm 0 100000>;
regulator-min-microvolt = <2250000>;
regulator-max-microvolt = <2250000>;
regulator-name = "fooregulator";
regulator-always-on;
regulator-boot-on;
voltage-table = <2250000 30>;
};
Before this patch:
fooregulator: failed to get the current voltage(-22)
After this patch:
fooregulator: Setting 2250000-2250000uV
fooregulator: 2250 mV
Signed-off-by: Vincent Whitchurch <vincent.whitchurch@axis.com>
Link: https://lore.kernel.org/r/20200902130952.24880-1-vincent.whitchurch@axis.com
Signed-off-by: Mark Brown <broonie@kernel.org>